BLCBR - HTZ FIBER VENEER MODULES

  • MSDS: BLCBR
  • Manufacturer: C E REFRACTORIES
  • Product Name: HTZ FIBER VENEER MODULES
  • National Stock Number: 5640-00N017147
Product Identification

Product ID:HTZ FIBER VENEER MODULES
MSDS Date:04/01/1988
FSC:5640
NIIN:00N017147
MSDS Number: BLCBR

Responsible Party
C-E REFRACTORIES
VALLEY FORGE, PA 19482
US

Emergency Phone: 215-337-1100

Info Phone: 203-285-9693

Cage: 8C482

Contractor
C-E REFRACTORIES DIV OF COMBUSTION ENGINEERING
KING OF PRUSSIA, PA 19406 US

Telephone: 215-337-1100

Cage: 8C482

Ingredients

ITS USEFUL LIFE (TEAR OUT) DUST GENERATION IS

RTECS: 9999999ZZ


PREC SHOULD BE TAKEN TO AVOID INHAL OF DUST. THIS

RTECS: 9999999ZZ


PRLNGD CONT. (ACUTE) IRRIT OF SKIN & UPPER RESP

RTECS: 9999999ZZ


INHAL OF CRYSTALLINE SILICA DUST. CRYSTALLINE SILICA

RTECS: 9999999ZZ


CALLED SILICOSIS, WHICH IS A SLOWLY DEVELOPING

RTECS: 9999999ZZ


SMOKING CAN INCREASE RISK OF INJURY. SUMMARY

RTECS: 9999999ZZ


CARCIN. ANIMAL STUDIES TO DATE ARE INCONCLUSIVE.

RTECS: 9999999ZZ


UNTIL FURTHER ANIMAL & HUMAN STUDIES ARE COMPLETE.

RTECS: 9999999ZZ


INORGANIC GLASS

CAS: 65997-17-3


ALUMINA ZIRCONIA SILICA FIBER


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: 20%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.05 MG/M3 RDUST9293


FOR SAFE USE/EXPOS. NIOSH/MSHA APPRVD RESP

RTECS: 9999999ZZ


SHOULD BE MINIMIZED BY USE OF DUST CONTROL

RTECS: 9999999ZZ


REMOVING CLOTHING.

RTECS: 9999999ZZ


SHOULD BE USED TO CONTROL/REDUCE AIRBORNE CONC.

RTECS: 9999999ZZ


2.0-5.0 F/CC-DISP DUST

RTECS: 9999999ZZ


EFFICIENCY FILTER. 50.0 F/CC-FULL FACEPIECE

RTECS: 9999999ZZ


LONG-TERM HLTH EFTS STUDIES, ENGINEERING CONTROL OF

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:HTZ FIBER IS AN ALUMINA ZIRCONIA
SILICA FIBER FOR REDUCING HEAT TRANSMISSION THRU FURNACE, KILN &
VESSEL STRUCTURES. THE CURRENT ACGIH, TLV FOR MINERAL WOOL FIBER,
AS DUST IS 10 MG/M3. CRYSTALLINE SIL ICA (CRISTOBALITE) WILL FORM
AFTER SERVICE AT TEMPS 1000C. THE "AFTER SERVICE" DUSTS CAN CONTAIN
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:SILICA, CRYSTALLINE: GROUP 2A (IARC).
Effects of Overexposure:HLTH HAZ: 0 TO 1% CRISTOBALITE CAS #14464-46-1
(CRYSTALLINE SILICA) WHICH CAN PRESENT A HLTH HAZ IF INHALED OVER
LONG PERIODS OF TIME. "ON THE BASIS OF INITIAL EXPERIMENTAL TESTS
IN ANIMALS & LIMITED EPIDEMILOGICAL STUDIES IN HUMAN POPULATIONS,
THE IARC HAS CONCLUDED THAT THERE IS LIMITED EVIDENCE FOR THE (SUPP
DATA)
Medical Cond Aggravated by Exposure:PRE-EXISTING UPPER RESPIRATORY AND
LUNG DISEASES SUCH AS, BUT NOT LIMITED TO, BRONCHITIS, EMPHYSEMA
AND ASTHMA.

First Aid

First Aid:SKIN: WASH OFF THOROUGHLY USING A MILD SOAP AND WATER.
INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR. SUPPORT
BREATHING (GIVE O*2/ARTF RESP) .

Fire Fighting

Flash Point:NON-COMBUSTIBLE
Extinguishing Media:USE EXTINGUISHING MEDIA APPROPRIATE TO THE
SURROUNDING AREA.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THIS PRODUCT IS A NON-COMBUSTIBLE
REFRACTORY.

Accidental Release

Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:BECAUSE OF POSS PRESENCE OF
CRYSTALLINE SILICA IN FIRE REFRACTORY LININGS, PARTICULAR CARE
SHOULD BE EXERCISED DURING TEAR-OUT TO MIN GEN OF DUST.
Other Precautions:ADHERENCE TO PROPER METHODS OF DUST SUPPRESSION AND
CONTROL IS IMPERATIVE. THE FOLLOWING ARE RECOMMENDED PRECAUTIONS TO
BE TAKEN DURING REMOVAL: EMPLOYEES SHOULD BE APPRISED OF HAZARDS
AND PROPER COND ITIONS AND PRECAUTIONS (SEE ING 4)

Exposure Controls

Respiratory Protection:PROVIDE WORKERS W/NIOSH/MSHA APPRVD DUST RESP
WHERE DUST LEVS MAY EXCEED PEL. NIOSH/MSHA APPRVD EQUIP ARE REC
WHEN AIRBORNE FIBER EXPOS LIMS ARE EXCEEDED. NIOSH/MSHA APPRVD
BRTHG EQUIP MAY BE REQ FOR NON-ROUTINE & EMER USE. VENT (SEE ING
7)
Ventilation:PROVIDE ADEQUATE GENERAL AND LOCAL EXHAUST VENTILATION TO
MEET PEL REQUIREMENTS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE CLOTHING AND VACUUM CLEAN PRIOR
TO REMOVING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: CARCIN OF CRYSTALLINE SILICA TO HUMANS. IARC HAS
CONVENED A SPECIAL TASK FORCE TO REVIEW CARCIN OF SILICA." THE
CURRENT OSHA PEL MAY BE CALCULATED BY USING THE FOLLOWING EQUATION,
5 M G/M3 DIVIDED BY PERCENT FREE SILICA + TWO, AVERAGED OVER AN 8
HR WORK SHIFT. WHEN THIS PROD IS REMOVED AFTER(SEE ING 11)

Chemical Properties

HCC:T6
Appearance and Odor:WHITE TO OFF-WHITE FIBER BLANKET, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

Disposal

Waste Disposal Methods:SOLID WASTE REGULATIONS APPLY. CONSULT LOCAL,
STATE AND FEDERAL REGULATORY AGENCIES TO DETERMINE BEST DISPOSAL
ALTERNATIVES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.